Is the fuse connected to the live wire
Witryna24 wrz 2015 · Does that not mean that both the live and neutral wires carry the same amount of current, alternatively? Yes,they do. As I have mentioned above. The live wire carries the current towards domestic appliances and others instruments and the neutral wire emerges from the appliance and carries the current back to source. WitrynaThe earth wire protects us from an electric shock. A switch should not be touched with wet hands. AH electrical appliances in a household circuit work at the same voltage. In a cable, green wire is the live wire. A fuse is connected to the live wire. A switch is connected to the neutral wire. Answer: Solution: False False False False True True
Is the fuse connected to the live wire
Did you know?
WitrynaFuses and circuit breakers protect electrical circuits and appliances. Fuses The fuse breaks the circuit if a fault in an appliance causes too much current to flow. This protects the wiring... WitrynaThere is no ground connection unless there is a fault and one of the wires touches something earthed. Then the other-wire becomes live. In (b) the battery negative has been connected to earth. It is grounded or neutralised and the other wire is 9 V with respect to earth.
WitrynaThe wire covered in brown plastic is the live wire. This carries the 230 V alternating potential difference from the power supply. The wire covered in blue plastic is the neutral wire and... Witryna31 mar 2024 · Also, a fuse should completely isolate the load or wiring from the supply by its burn off or on removal. Since, neutral is not a live conductor coming from the source, disconnecting a neutral line can only open the current path through neutral. But, the live phase still carries the charge.
Witryna42 Likes, 2 Comments - Byrne Electrical Ltd (@byrneelectricalltd) on Instagram: "My most challenging and time consuming @cpfusebox board change today. So the story ... WitrynaIn household circuit, is a fuse wire connected in series or in parallel? Medium. View solution > Fuses are connected in _____ to the live wire: Easy.
Witryna28 wrz 2016 · "The purpose of grounding the electrical system as stated in NFPA 70: National Electrical Code (NEC) is, “To limit the voltage imposed by lightning, line surges, or unintentional contact with higher-voltage lines that will stabilize the voltage to earth during normal operation.”
WitrynaThe live wire, having a voltage of around 230 V, is the most dangerous one As a result of this, fuses and switches are always connected to the live wire This means that when a switch is turned off (or a fuse blows) a device will no longer be connected to the live supply The circuit symbol for a fuse dj jaivane sdudla samWitrynaThe fuse or circuit breaker must be connected in the live wire side of a domestic circuit to ensure that it keeps high voltage from reaching the user, or surroundings, if a fault develops.... dj jaivane sample pack downloadWitryna13 paź 2024 · Connect the New Single-Pole Switch. Connect the green grounding screw on the switch to the circuit's bare copper or green grounding wires. If the circuit has just a single grounding wire, then it … dj jaivane shaka zulu mp3 download fakazaWitryna22K views, 110 likes, 5.6K loves, 7.5K comments, 460 shares, Facebook Watch Videos from Bradd: AKO ULITTT dj jaivane shaka zulu youtubeWitrynaThe fuse is connected to one of the wires inside the cable. (i) Which one of the wires inside the cable is the fuse connected to? [1 mark] (ii) The fuse is a thin wire inside a closed glass tube. The wire acts as a resistor. What effect does a current through a wire have on the wire? [1 mark] dj jaivane shaka zulu mp3 song downloadWitrynaIsolation: If the neutral fuse blows first the circuit would stay live. It's generally best to disconnect the circuit from mains. Polarity: Many countries don't use polarised plug and sockets on single-phase plugs. This means that the fuse in … dj jaivane sample packsWitrynaThe live wire and neutral wire, coming from the electric pole, enter a box fitted just outside our house which has a main fuse F1. The fuse is connected in series with the live wire. This is done so because it is only the live wire which has a high potential of 220 volts unlike the neutral wire which carries zero potential. dj jaivane real name